Multi Function Tester
Model No: 6016

Catalogue

Continuity Measurement

Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.

Insulation Measurement

Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.

Loop Impedance Measurement

A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.

PSC / PFC Measurement

The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.

RCD Measurement

The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).

Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application.

Earth Measurement

Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.

Phase rotation

KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.

Voltage Measurement

In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.

Range

20/200/2000? (Auto-ranging)

Open circuit voltage (DC)

5V±20% (*1)

Short circuit current

Greater than 200mA

Accuracy

±0.1? (0 - 0.19?) ±2%rdg+8dgt (0.2 - 2000?)

Insulation Resistance

Range

20/200M? (Auto-ranging), 20/200/2000M? (Auto-ranging)

Open circuit voltage (DC)

250V+25% -0%, 500V+25% -0%, 1000V+20% -0%

Rated current

1mA or greater @ 250k? , 1mA or greater @ 500k?, 1mA or greater @ 1M?

Accuracy

±2%rdg+6dgt (0 - 19.99M?) ±5%rdg+6dgt (20 - 200M?), ±2%rdg+6dgt (0 - 199.9M?) ±5%rdg+6dgt (200 - 2000M?)

Loop Impedance

Function

L-PE, L-PE (ATT), L-N / L-L

Rated Voltage

100 - 260V 50/60Hz, L-N: 100 - 300V L-L: 300 - 500V 50/60Hz

Nominal Test Current at 0? External Loop: Magnitude/ Duration (*2)

20?: 6A/20ms 200?: 2A/20ms 2000?: 15mA/500ms, L-N: 6A/60ms N-PE: 10mA/approx. 5s, 20?: 6A/20ms

Range

20/200/2000? (Auto-ranging), 20/200/2000? (Auto-ranging) (L-N < 20?), 20?

Accuracy

±3%rdg+4dgt(*3) ±3%rdg+8dgt(*4), ±3%rdg+6dgt (*3) ±3%rdg+8dgt(*4), ±3%rdg+4dgt (*3) ±3%rdg+8dgt(*4)

PSC (L-N / L-L) / PFC (L-PE)

Function

PSC , PFC, PFC (ATT)

Rated Voltage

100 - 500V 50/60Hz, 100 - 260V 50/60Hz

Nominal Test Current at 0? External Loop: Magnitude/ Duration (*5)

6A/20ms, 6A/20ms 2A/20ms 15mA/500ms, L-N: 6A/60ms N-PE: 10mA/approx. 5s

Range

2000A/20kA Auto-Ranging

Accuracy

PSC / PFC accuracy is derived from measured loop impedance specification and measured voltage specification

RCD

Function

X1/2, X1, X5 ,Ramp, Auto

Trip current setting

10/30/100/300/ 500/1000mA, 10/30/ 100mA ,10/30/ 100/300/ 500mA

Trip current Duration

2000ms, G: 550ms S: 1000ms, 410ms, Goes up by 10% from 20% to 110% G:300ms/ S:500ms X10 times

Rated Voltage

230V+10%-15% 50/60Hz

Accuracy

AC Type: -8% - -2% A Type: -10% - 0%, AC Type: +2% - +8% A Type: 0% - +10%, AC Type: ±4% A Type: ±10%

Trip time

±1%rdg+3dgt

RCD (Uc)

Function

UC

Rated Voltage

230V+10% - 15% 50/60Hz

Range

100.0V

Test current

? 1/2I?n (max150mA)

Accuracy

+5% - +15%rdg, ±8dgt

Earth

Range

20/200/2000? Auto-Ranging

Accuracy

20?: ±3%rdg+0.1? 200/2000?: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)

Phase Rotation

Rated Voltage

50-500V 50/60Hz

Remarks

Correct phase sequence: are displayed "1.2.3" and cycle mark Reversed phase sequence: are displayed "3.2.1" and cycle mark

Volts

Function

Volts, Frequency

Rated Voltage

25 - 500V, 45 - 65Hz

Measuring range

25 - 500V, 45 - 65Hz

Accuracy

±2%rdg+4dgt, ±0.5%rdg+2dgt

Applicable standards

IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031, IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)

Power source

LR6 X 8

Dimensions

136(L) X 235(W) X 114(D)mm

Weight

1350g (including batteries.)

Included Accessories

7188A (Distribution board fuse test lead set) 7281 (Test leads with remote control switch) 7218A (Power cord [EU]) (*6) 7228A (Earth resistance test leads) 8032 (Auxiliary earth spikes) 8212-USB (USB adaptor with KEW Report (Software)) 9142 (Carrying case) 9121 (Shoulder strap) Cord case, Buckle, Battery, Instruction manual

Optional Accessories

8212-RS232C (RS232C adaptor with KEW Report (Software))